Junger-audio b42 - Dynamics Processor Manuel d'utilisateur Page 19

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 44
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 18
3. INSTALLATION
Operation manual b42, chapter 3 -installation- page 3-5
The digital dynamics processor b42 can be remote-controlled by
means of serial remote RS-422.
use : remote-controlled changeover of presets
protocol:
available on request
connector: D-SUB 9pin, input - female
output - male
Pin assignments
The cable is wired 1:1 completely, the shield of the cable must be connected
on both ends!
REMOTE IN
Pin Signal name Functions
1 DSR + out Data set ready
2 DSR - out
3 SENSE in Interrogation Remote
4 RXD + out Receive data
5 RXD - out
6 DTR + in Data terminal ready
7 DTR - in
8 TXD + in Transmit data
9 TXD - in
REMOTE OUT
Pin Signal name Functions
1 DSR + in Data set ready
2 DSR - in
3 GND GND
4 RXD + in Receive data
5 RXD - in
6 DTR + out Data terminal ready
7 DTR - out
8 TXD + out Transmit data
9 TXD - out
Electrical specification:
signal in-/outputs TTL-level
3.7.3
SERIAL REMOTE
CONTROL
(RS-422)
Vue de la page 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 43 44

Commentaires sur ces manuels

Pas de commentaire